Jump to content

IMB5 Installation Manual: Difference between revisions

From Teltonika Security Wiki
No edit summary
No edit summary
Line 41: Line 41:
| Pulse radiated power || Up to 1 mW
| Pulse radiated power || Up to 1 mW
|}
|}
=== Entering Service Mode ===
=== Entering Service Mode ===
The Service Mode can be activated if the ID card is lost, the battery is discharged, or the car is being repaired. It is activated by entering a '''PIN code'''.
The Service Mode can be activated if the ID card is lost, the battery is discharged, or the car is being repaired. It is activated by entering a '''PIN code'''.
* '''Factory preset PIN:''' Printed on the immobilizer sticker.
* '''Factory preset PIN:''' Printed on the immobilizer sticker.
* '''Entering PIN (Example 2113):'''  
* '''PIN entering logic:'''
# Turn ignition ON/OFF and count System LED flashes (not ID card LED!).
[[File:Entering_Service_Mode.png|center|800px|PIN code entering by ignition or authorization button]]
# Wait for the LED to confirm each digit (maximum 2 seconds between actions).
 
'''Steps to enter PIN (Example 2113):'''
# '''By Ignition:''' Turn ignition ON/OFF and count System LED flashes. Wait for double flashes to confirm each digit.
# '''By Button:''' Press and hold the button for 1 second for each unit of the digit (e.g., press 2 times for digit "2").
# After the last digit, wait for '''Triple flashes''' to enter Pairing Mode or '''Quadruple flashes''' for Service Mode.
 
<div style="clear: both;"></div>


=== Available Immobilizer Settings (FN Functions) ===
=== Available Immobilizer Settings (FN Functions) ===

Revision as of 17:12, 7 April 2026

Immobilizers > IMB5 Installation Manual

IMB5 Installation Manual

IMB5 Vehicle Immobilizer

System Unit and ID card
Purpose Car theft prevention
Technology 2-way encrypted RF
Frequency 2.4 GHz
Temperature -40°C to +85°C


IMB5 Immobilizer Purpose

The purpose of the immobilizer "TELTONIKA IMB5" is car theft prevention.

  • The driver is identified when the ID card is present inside the communication area.
  • If no ID card is present, the device prevents engine start or shuts down the running engine.
  • Up to 5 ID cards and one radio relay (IMB6) can be paired with the System unit.

Specifications

Parameter Value
Operating temperature range -40°C to +85°C
Supply voltage 9-15 VDC
Average consumption current Up to 10 mA (at 12V)
Average control distance 2-4 meters
Communication frequency 2.4 GHz
Pulse radiated power Up to 1 mW

Entering Service Mode

The Service Mode can be activated if the ID card is lost, the battery is discharged, or the car is being repaired. It is activated by entering a PIN code.

  • Factory preset PIN: Printed on the immobilizer sticker.
  • PIN entering logic:
PIN code entering by ignition or authorization button
PIN code entering by ignition or authorization button

Steps to enter PIN (Example 2113):

  1. By Ignition: Turn ignition ON/OFF and count System LED flashes. Wait for double flashes to confirm each digit.
  2. By Button: Press and hold the button for 1 second for each unit of the digit (e.g., press 2 times for digit "2").
  3. After the last digit, wait for Triple flashes to enter Pairing Mode or Quadruple flashes for Service Mode.

Available Immobilizer Settings (FN Functions)

The IMB5 can be adjusted to specific vehicle requirements by changing these settings:

FN Function SN (Setting Number) Description
FN-11 End of FN settings Exits the setup mode.
FN-21 Immobilization Signal SN-1: Signal ON 20s after ignition OFF. SN-2: Signal OFF.
FN-22 Anti-Carjack SN-1: OFF. SN-2/3/4: Triggers by ignition ON or door opening without ID card.
FN-45 Low Battery Warning SN-1: ON (4 double buzzer signals when ignition ON). SN-2: OFF.
FN-51 OC1 Output Purpose Configures Optional Control 1 (Relay NC/NO, Alarm system link, etc.).
FN-81 Change PIN code Used to change the system security PIN.
FN-91 Factory Reset Restores default factory settings and the default PIN.

Wiring Diagram Connections

IMB5 Connection Scheme
Wire Color Connection / Function
Black Ground (Car's body)
Red +12V Battery
Yellow Ignition switch
Blue OC1 (Optional Control 1)
Grey Buzzer
Brown Authorization Button / Doors (-) Input

Pairing ID Cards

  1. Enter the PIN code for IMB5.
  2. Within the 2-second interval when the LED blinks with triple flashes, turn the ignition ON and OFF.
  3. Press and hold the button on the new ID card (must be in passive/orange mode).
  4. A 1-second flash indicates the ID card is successfully paired.
  5. Note: All previously paired ID cards are deleted when the first new one is paired.

Safety Warning

The user MUST change the PIN code after the installation and do not save it inside the car.