Jump to content

SMS Commands: Difference between revisions

From Teltonika Security Wiki
m Gintautas.K moved page SMS and Voice Commands to SMS Commands
No edit summary
 
Line 3: Line 3:
# '''1234''' – the System PIN code.
# '''1234''' – the System PIN code.
# Engine start / stop and stand-alone engine pre-heater turn ON / turn OFF commands are available only if the appropriate function settings are ON.
# Engine start / stop and stand-alone engine pre-heater turn ON / turn OFF commands are available only if the appropriate function settings are ON.
# The System automatically ends the call if no button is pressed within 45 seconds.
</div>
</div>



Latest revision as of 10:56, 14 January 2026

Notes:

  1. 1234 – the System PIN code.
  2. Engine start / stop and stand-alone engine pre-heater turn ON / turn OFF commands are available only if the appropriate function settings are ON.

Phonebook

SYNTAX DESCRIPTION SAMPLE
SN? ˽ NNNN Add phonenumber NNNN to ? phonebook position (position number ? - 1 to 5) 1234 SN2 37068412345
SN0 ˽ NNNN Add phonenumber NNNN to first empty phonebook position 1234 SN0 37068412345
SR? Clear ? Phonebook position (position number ? - 1 to 5) 1234 SR2
SI Get SMS with all preprogramed numbers 1234 SI
SH1 Allow answer to any number and process SMS commands from any number 1234 SH1
SH0 Allow answer only to registered numbers and process SMS command only from registered numbers 1234 SH0

GPRS Settings

SYNTAX DESCRIPTION SAMPLE
SGA ˽ APN Set APN (ask your network provider) 1234 SGA internet
SGU ˽ USER Set user name (ask your network provider, leave blank if not required) 1234 SGU omni
SGP ˽ PASS Set password (ask your network provider, leave blank if not required) 1234 SGP omni
APNAUTO Set default APN, user name and password according to network code 1324 APNAUTO
REGISTER Register your alarm system on alarmserver.net 1234 REGISTER
SGSE ˽ STATE Turn on/off communication with Alarm server (STATE = 1 - on; STATE = 0 - off) 1234 SGSE 1
GPRS : STATE Turn on/off communication with Alarm server (STATE = 1 - on; STATE = 0 - off) 1234 GPRS:1
SGSR ˽ ExTxSxGxFxCxZx Alarm server setings. x=1 - enable; x=0 - disable.

E - Report events (arm, disarm, alarm), Z - Report zones (open/close door, hood, trunk..), T - Report technical information (battery voltage, temperature, GSM signal level), S - Report system status (armed, disarmed, open zones etc), G - Report geolocation (GPS and GSM towers information) F - Forward data to 3rd party server C - Use custom address for reporting to Alarm server Note: it is not necessary to send all settings if you want to disable geolocation reporting only and leave other settings unchanged you can send: SGSR*G0*

1234 SGSR E1T0S1G0F1C0
SGSP ˽ PERIOD Periodic report. PERIOD - value from 0 to 6. (0 - disabled; 1 - every 10min; 2 - every 30min; 3 - every 60min; 4 - every 6h; 5 - every 1d; 6 - every 2d) 1234 SGSP 2
SGSC ˽ CMS CMS - corporate account number 1234 SGSC 12345
SGSA ˽ IP:PORT IP address and port used for report forwarding to 3rd party server (SGSR*F1) or it can be used as custom reporting address instead www.alarmserver.net (SGSR*C1) 1234 SGSA

192.168.101.010:1010

SGTX Enable/Disable GPS tracking (X=1 - enable; X=0 - disable) 1234 SGT1
GPS : STATE Enable/Disable GPS tracking (STATE=1 - enable; STATE=0 - disable) 1234 GPS:0
ROAMING : STATE Enable/Disable communication with server on roaming (STATE=1 - enable; STATE=0 - disable) 1234 ROAMING:1
REPORT Enable full reporting to alarmserver.net (system will report events, zones, technical info, system status, geolocation, tracking and periodical reporting every 10min also will be enabled) 1234 REPORT
TCPCONTROL : STATE Enable/Disable alarm system control over internet (STATE=1 - enable; STATE=0 - disable) 1234 TCPCONTROL:1
TRACKING : ACCUR Change tracking accuracy, ACCUR – value from 1 to 5. (1 – very high, 2 – high, 3 – medium, 4 – low, 5 - very low) For Very high and high tracking accuracy VOUCHER code is required – check on alarmserver.net 1234 TRACKING:3
PINGPER : PERIOD Setup short ping period, PERIOD – value from 0 to 5. (0 – disabled, 1 – 1min, 2 – 2min, 3 – 3min, 4 – 5min, 5 – 10min) Short ping is used to detect when alarm system is loosing connection with server. To enable short ping VOUCHER code is required – check on alarmserver.net 1234 PINGPER:0

Other Settings

SYNTAX DESCRIPTION SAMPLE
SERVICE : STATE Enter/exit service mode (STATE = 1 - enter; STATE = 0 -exit) 1234 SERVICE:1
RESET : X X=M - reset modem; X=F - full system reset 1234 RESET:M
UPGRADE Upgrade device firmware (upgrade may take 5-10min, SMS will be send in case of success of failure) 1234 UPGRADE
PIN : PPPP Change PIN. PPPP - new PIN code (4 digits, 1-9) 1234 PIN:1235
SL? Set periodic SMS test interval, ? represents interval in days (1 to 4 days) 1234 SL4
ST ˽ temp Adjust temperature sensor, temp - current temperature (+26, -8 etc.) 1234 ST +26
SU ˽ voltage Set low battery warning voltage (type 119 for 11.9V, default 11.8V) 1234 SU 119
SF ˽ FN=SN Set alarm system function FN seting number to SN (22=1) 1234 SF 22=1
SW ˽ time Set engine preaheater operation time period in minutes 1234 SW 20
SM ˽ map Select maps provider. Where map 0 or 1 (0 - maps.google.com; 1 - maps.yandex.ru) 1234 SM 1
LBSURL : url Select location provider (by GSM data). Where url 0 or 1 (0 – opencellid.org, 1 – xinit.ru) 1234 LBSURL:0
F ˽ NNNN ˽ text Forward text to NNNN 1234 F 37068412345 ELITA GN8
X1 ˽ bal Get SIM card balance, where bal is network provider specific command (*245#, *100# etc.) 1234 X1 *254#
SMSREPCNT ˽ X Set amount of SMS sending tries in case device failing to send SMS, because of network error (default: 3)

Messaging Settings

SYNTAX DESCRIPTION SAMPLE
Default
1-as 2 – 5-as
S?Mx Mandatory call on alarm 1234 S1M1
S?Cx Call on alarm 1234 S2C1
S?Vx SMS on alarm 1234 S3V1
S?Ax SMS on arm 1234 S1A1
S?Dx SMS on disarm 1234 S1D1
S?Ex SMS on remote engine start/stop or engine preaheater on/off 1234 S1E1
S?Tx Trouble SMS 1234 S2T1
S?Px Periodic test SMS 1234 S2P1
S?Fx SMS forwarding 1234 S1F1
S?Qx SMS command must be with PIN 1234 S1Q1
S?Xx Control over SMS forbiden 1234 S1X0
S?Sx SMS in smartphone format (Android only) 1234 S1S1
S?Kx Arm/Disarm with short call (CLIP) 1234 S1K1
S?Ox START/STOP engine remotely with short call (CLIP) 1234 S2O1
S?Wx Turn ON/OFF engine preheater with short call (CLIP) 1234 S3W1
S?Ux Turn ON/OFF push notifications 1234 S1U1

? - position number in phonebook (1 to 5)
x = 1 - Enabled
x = 0 - Disabled

Personal Messaging Settings

SYNTAX DESCRIPTION SAMPLE
Default
1-as 2 – 5-as
SMx Mandatory call on alarm 1234 SM1
SCx Call on alarm 1234 SC1
SVx SMS on alarm 1234 SV1
SAx SMS on arm 1234 SA1
SDx SMS on disarm 1234 SD1
SEx SMS on remote engine start/stop or engine preaheater on/off 1234 SE1
STx Trouble SMS 1234 ST1
SPx Periodic test SMS 1234 SP1
SFx SMS forwarding 1234 SF1
SQx SMS command must be with PIN 1234 SQ1
SXx Control over SMS forbiden 1234 SX0
SSx SMS in smartphone format (Android only) 1234 SS1
SKx Arm/Disarm with short call (CLIP) 1234 SK1
SOx START/STOP engine remotely with short call (CLIP) 1234 SO1
SWx Turn ON/OFF engine preheater with short call (CLIP) 1234 SW1
SUx Turn ON/OFF push notifications 1234 SU1

x = 1 - Enabled
x = 0 - Disabled

Control and status commands

SYNTAX DESCRIPTION SAMPLE
0 or I Get system status 1234 I
A Arm system 1234 A
D Disarm system 1234 D
C Clear alarm 1234 C
G Start engine 1234 G
Q Stop engine 1234 Q
61 Turn on optional control 1234 61
60 Turn off optional control 1234 60
99 Block the engine 1234 99
90 Unblock the engine 1234 90
X5 Get location SMS using GSM 1234 X5
X6 Get location SMS using GPS 1234 X6
PANIC : M Panic mode. Direction indicators and/or siren go ON for 30s. M=L – with siren, M=S without siren 1234 PANIC:L
OPENTRUNK Open cars trunk 1234 OPENTRUNK
ON : 1 arba 2 Turn on system output configured as AUX1 or AUX2 1234 ON:1
OFF : 1 arba 2 Turn off system output configured as AUX1 or AUX2 1234 OFF:1
V Get SMS with system version 1234 V
BI Get SMS with system BI number 1234 BI
USTS Update system status to server 1234 USTS
GETOPEN Get open zones by SMS 1234 GETOPEN
GETFN Get all function settings (21=1 means FN21 SN1) 1234 GETFN
GETCAR Get current vehicle group and subgroup 1234 GETCAR

CAN BUS Monitored Zones

SYNTAX DESCRIPTION SAMPLE
CANENABLE : zone Enable zone monitoring over CAN-BUS 1234 canenable:ENGINE
CANDISABLE : zone Disable zone monitoring over CAN-BUS 1234 CANdisable:HOOD
zones: hood original hood sensor 1234 CANdisable:door
door original hood sensors
trunk original trunk sensor
ignition ignition status monitoring
engine running engine status monitoring
omsensor alarm from original sensor
remote arming/disarming from original remote or keyless access system

Engine Start Settings

SYNTAX DESCRIPTION SAMPLE
STARTTIME : TIME Remote engine start duration in minutes (TIME from 5min to 45min) 1234 STARTTIME:15
STARTP : STATE Enable/disable periodic engine start (STATE=1 - enable; STATE=0 - disable) 1234 STARP:1
STARTPERIOD : PERIOD Periodic engine start period in hours (PERIOD from 2h to 24h) 1234 STARTPERIOD:3
STARTTIMEP : TIME Periodic engine start duration in minutes (TIME from 5min to 45min) 1234 STARTPERIODP:15
STARTT : STATE Enable/disable engine start by low engine temperature (STATE=1 - enable; STATE=0 - disable) 1234 STARTT:1
STARTTEMPERATURE : TEMP Low engine temperature in °C (TEMP from 0°C to -25°C) 1234 STARTTEMPERATURE:-10
STARTTIMET : TIME Low temperature engine start duration in minutes (TIME from 5min to 45min) 1234 STARTTIMET:15
STARTV : STATE Enable/disable engine start by low battery voltage (STATE=1 - enable; STATE=0 - disable) 1234 STARTV:0
STARTVOLTAGE : VOLT Low battery voltage in volts (VOLT from 10V to 12,5V) 1234 STARTVOLTAGE:11,8
STARTTIMEV : TIME Low battery voltage engine start duration in minutes (TIME from 5min to 45min) 1234 STARTTIMEV:15
STARTC : STATE Enable/disable engine start by calendar (STATE=1 - enable; STATE=0 - disable) 1234 STARTC:0
STARTCALENDAR : CAL Engine start calendar (times for every weekday) CAL = 8:00,8:00,8:00,8:00,8:30,99:99,99:99 - Monday to Thursday engine start at 8:00, Friday - 8:30, Saturday and Sunday - no engine start 1234 startcalendar:8:00, 8:00, 8:00, 8:00 8:30, 99:99, 99:99
STARTTIMEC : TIME Engine start by calendar duration in minutes (TIME from 5min to 45min) 1234 STARTTIMEC:10

NOTES

  • SMS message must be started with a valid 4-digit alarm system PIN code.
  • SMS commands are not case sensitive (1234 D and 1234 d are the same disarm command).
  • It is possible to add as many commands as you want, unless the total message length exceeds 160 symbols.
  • Commands F and X1 must be sent in separate SMS messages or added at the end of a command set (e.g., 1234 A F 37067012345 Hello, this is a forwarded SMS).
SMS command example
1234 A — Arm system, 1234 is alarm system PIN
SMS command set example
1234 SN1 37067012345 S1D1 — Add phone number 37067012345 to 1st phonebook position, enable SMS on disarm to 1st number, 1234 is alarm system PIN

NOTES for legacy devices with firmware version below v1.06

  • SMS message must be started with a valid 4-digit alarm system PIN code.
  • In front of every command * must be added. Also, * must be added instead of ˽ (space symbol) inside the command.
  • At the end of a command or command set (if multiple commands added) *# must be added.
  • SMS commands are not case sensitive (1234*D*# and 1234*d*# is the same disarm command).
  • It is possible to add as many commands as you want, unless the total message length exceeds 160 symbols.
  • Commands F and X1 must be sent in separate SMS messages or added at the end of a command set. In this case, do not add *# at the end (e.g., 1234*A*F*37067012345*Hello, this is a forwarded SMS).
SMS command example
1234*A*# — Arm system, 1234 is alarm system PIN
SMS command set example
1234*SN1*37067012345*S1D1*# — Add phone number 37067012345 to 1st phonebook position, enable SMS on disarm to 1st number, 1234 is alarm system PIN